• All Products

      • Charge Air Coolers
        • Charge Air Coolers

          Used to cool the hot, compressed air from the turbo before it reaches the engine, the intercoolers improve engine efficiency and reduce emissions for marine and land-based stationary engines.

      • Exhaust Gas Heat Exchangers
        • Exhaust Gas Heat Exchangers

          Exhaust gas heat exchangers are designed to recover waste heat energy from the exhaust stream of reciprocating engine powered generating sets.

      • Fuel Coolers
        • Fuel Coolers

          Bowman 'copper free' fuel coolers are compact, highly efficient heat exchangers suitable for fuel conditioning rigs in the automotive testing industry.

      • Header Tank Heat Exchangers
        • Header Tank Heat Exchangers

          Engine coolant header tank heat exchangers for marine propulsion, gensets or stationary land-based engines.

      • Hot Tub Heat Exchangers
        • Hot Tub Heat Exchangers

          Bowman EC 80-5113-1T heat exchangers provide a new solution for heating spas and hot tubs in just a fraction of the time taken by traditional electric heaters.

      • Hydraulic Oil Coolers
        • Hydraulic Oil Coolers

          Highly efficient heat transfer solutions for cooling marine, land-based and underground hydraulic systems.

      • Inline Plate Type Heat Exchangers
        • Inline Plate Type Heat Exchangers

          Bowman inline plate heat exchangers are a compact, economical solution for high efficiency heat transfer.

      • Marine Engine Coolers
        • Marine Engine Coolers

          Bespoke cooling solutions for a range of popular marine engines from major OEMs, including coolant heat exchangers, charge air coolers, plus combined heat exchangers and exhaust manifolds, suitable for cooling marine engines up to 1 MW.

      • Marine Transmission Oil Coolers
        • Marine Transmission Oil Coolers

          Bowman has a range of highly efficient oil coolers designed for marine and industrial engines and transmissions.

      • Electric and Hybrid Coolers
        • Electric and Hybrid Coolers

          Efficient heat exchangers for cooling electric marine motors, hydrogen fuel cells, battery packs, chargers, AC-DC converters, DC-DC converters, inverters and associated equipment for electric and hybrid marine propulsion and charging systems.

      • Shell and Tube Heat Exchangers
        • Shell and Tube Heat Exchangers

          Highly efficient heat transfer solutions for cooling a variety of applications where air and fluids need to be cooled by fluids.

      • Stainless Steel Heat Exchangers
        • Stainless Steel Heat Exchangers

          Many applications require stainless steel shell and tube heat exchangers and Bowman provide a standard range of units that are suitable for cooling or heating a variety of fluids.

      • Swimming Pool Heat Exchangers
        • Swimming Pool Heat Exchangers

          Bowman swimming pool heat exchangers are renowned for reliability and efficiency. Whether heating your pool with a traditional boiler or a renewable energy source, Bowman is the obvious choice.

    • All Applications

      • Automotive Testing
        • Automotive Testing

          Premium quality heat exchangers and oil coolers for precise temperature control of engines under test cell development conditions.

      • CHP / Co-Generation
        • CHP / Co-Generation

          Recovering waste heat energy from engine powered generating sets for biogas, diesel and natural gas applications up to 1 MW.

      • Engine Cooling Solutions
        • Engine Cooling Solutions

          Efficient cooling for stationary / land-based engines where air cooling is either unavailable or inappropriate.

      • Electric & Hybrid Marine
        • Electric & Hybrid Marine

          The reliable solution for cooling Electric & Hybrid Marine Propulsion Systems.

      • Industrial Hydraulics
        • Industrial Hydraulics

          A comprehensive oil cooling solution for industrial hydraulic control systems, plus high temperature and mining applications.

      • Marine Hydraulics
        • Marine Hydraulics

          A complete solution for cooling complex on-board hydraulic equipment, including thruster and stabiliser systems.

      • Marine Propulsion
        • Marine Propulsion

          The complete cooling solution for marine engine propulsion, including the latest electric and hybrid systems.

      • Hot Tubs / Spas
        • Hot Tubs / Spas

          An energy efficient solution for heating hot tubs and swim spas faster, significantly reducing heat-up time for guest change-over periods.

      • Swimming Pool
        • Swimming Pool

          Quality heat exchangers for efficient swimming pool heating, using boiler or renewable energy heat sources.

  • Distributors
  • News
  • Knowledge Centre
  • Downloads
  • About Us
  • Contact Us

FG100-5107-2 – with NPT connections – 580,000 Btu/h

The perfect choice for heating hot tubs, spas and small swimming pools with a domestic boiler.
Typical Heat Transfer from a boiler:

580,000 Btu/h

The Bowman FG100-5107-2 is an efficient shell and tube heat exchanger, which is suitable for swimming pools up to 9,600 ft³, via a boiler heat source. The cast end covers are finished in ‘C’ coat, an advanced technology coating, which is highly corrosion-resistant and the unit is available with either a titanium, cupro-nickel, or stainless steel tube core.

Product Benefits

Proven

Heats pools fast, reducing energy costs

easy to Install

2 1/2” NPT threaded end covers with thermostat pocket

Durability

Salt water and mineral rich fresh water compatible

Simple to maintain

Easy disassembly for routine maintenance

Titanium Models

Full 10 year warranty on titanium materials

Typical Heat Transfer from a boiler:

580,000 Btu/h

The Bowman FG100-5107-2 is an efficient shell and tube heat exchanger, which is suitable for swimming pools up to 9,600 ft³, via a boiler heat source. The cast end covers are finished in ‘C’ coat, an advanced technology coating, which is highly corrosion-resistant and the unit is available with either a titanium, cupro-nickel, or stainless steel tube core.

Product Benefits

Proven

Heats pools fast, reducing energy costs

easy to Install

2 1/2” NPT threaded end covers with thermostat pocket

Durability

Salt water and mineral rich fresh water compatible

Simple to maintain

Easy disassembly for routine maintenance

Titanium Models

Full 10 year warranty on titanium materials

Typical Heat Transfer from a boiler:

580,000 Btu/h

The Bowman FG100-5107-2 is an efficient shell and tube heat exchanger, which is suitable for swimming pools up to 9,600 ft³, via a boiler heat source. The cast end covers are finished in ‘C’ coat, an advanced technology coating, which is highly corrosion-resistant and the unit is available with either a titanium, cupro-nickel, or stainless steel tube core.

Features

Simple to Maintain

Simple to Maintain

The modular design means that end covers on all models are easily removable, enabling the tube stack to be easily extracted from the outer ‘shell’ ensuring all maintenance requirements are simple and straightforward.

Energy Saving

Energy Saving

The faster a pool gets to the required temperature, the lower the energy costs! Bowman units heat pools up to three times faster and the result is reduced energy costs and improved pool availability.

Shell and Tube Design

Shell and Tube Design

The tube stack is packed with tubes and internal baffles to provide the largest and most effective surface area, enabling the unit to heat pools considerably faster than some competitors’ products.

Specification

Technical Drawing / Dimensions

Note – All dimensions in inches

Performance Chart

*Not suitable for use on pools fitted with salt water chlorinators or salt water pools.

Performance Graphs / Pressure Drop Curves

Water Flow

As the graphs and table above illustrate, providing the right water flow volume is vital to the performance of the heat exchanger. If the flow rate of either the hot water supply, or the pool water circuit is too low, the heat exchanger will not perform at its designed efficiency and will be unable to transfer all the available heat energy in to the pool water. For more information, please read: Why doesn’t my pool heat up faster?

Installation Diagram

Refer to the following diagram for how to install the heat exchanger in the pool system. The heat exchanger can be mounted either horizontally or vertically as per the schematic.

If an automatic dosing system is added, it must be installed after the heat exchanger on the return to the pool.

Technical Drawing / Dimensions

Note – All dimensions in mm (except threaded connectors)

Performance Chart

*Not suitable for use on pools fitted with salt water chlorinators or salt water pools.

Performance Graphs / Pressure Drop Curves

Water Flow

As the graphs and table above illustrate, providing the right water flow volume is vital to the performance of the heat exchanger. If the flow rate of either the hot water supply, or the pool water circuit is too low, the heat exchanger will not perform at its designed efficiency and will be unable to transfer all the available heat energy in to the pool water. For more information, please read: Why doesn’t my pool heat up faster? 

Performance Graphs / Pressure Drop Curves

The EC120-5113-3 is supplied with ‘Universal Fit’ composite end covers, designed for use with either 1.5” nominal pipe size (48mm O/D) or metric 50mm O/D pool pipework. The ‘socket union’ component enables either diameter to be accommodated, as shown on the following cross section illustration.

Installation Diagram

Refer to the following diagram for how to install the heat exchanger in the pool system. The heat exchanger can be mounted either horizontally or vertically as per the schematic.

If an automatic dosing system is added, it must be installed after the heat exchanger on the return to the pool.

Downloads

No download content found.

5107-2 Product Profile (North America)

Find specific information, drawings, performance graphs and pressure drop data on the FG100-5107-2 swimming pool heat exchanger product profile leaflet.

Download

Related Products

FAQs

FAQs

If your pool isn’t heating up to the required temperature, there are a few possible causes. Using this checklist could help you locate the problem:

1: Do I have enough energy?
Whether heating your pool with a gas boiler, solar panels, a heat pump, or another energy source, it is important you have enough energy to do the job.

2: Do I have the right heat exchanger?
A common misconception is the larger the heat exchanger, the faster it heats the pool! However, this isn’t necessarily the case. There are many types of heat exchangers used to heat swimming pools and they differ dramatically in design, performance and heat transfer efficiency.

3: My heating system is adequate but my pool still fails to heat up!
Flow rates of both the hot and cold fluids are vital for the heat exchanger to transfer thermal energy to the pool. If the hot water flow rate is too low, the available energy will not be passed through the heat exchanger. However, the flow rate of the pool water is equally important.

4: And if you’ve done all that…
Even if all the equipment is adequately sized, there may still be other parts of the system creating issues that will need to be checked.

5: In summary…
This is a summary of a more detailed article designed to help identify problems with pool heating and heat exchangers. Read the complete article here.

More product information on Bowman swimming pool heat exchangers.

Related Articles

Get in Touch

If you have a specific enquiry or would like to talk to one of our technical sales engineers, you can contact us by phone or email, using the contact details below. For more general enquiries, simply fill in and return the contact form for a fast response.

 

Tel: +44 (0)121 359 5401
E-mail: [email protected]

Local Distributors

A network of authorised, international Bowman distributors, who hold product stocks and provide local service, is also available.

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.