Life in the ‘deep freeze’!
Bowman CHP heat exchangers provide vital heating for the Halley VI Antarctic research station.
Used to cool the hot, compressed air from the turbo before it reaches the engine, the intercoolers improve engine efficiency and reduce emissions for marine and land-based stationary engines.
Exhaust gas heat exchangers are designed to recover waste heat energy from the exhaust stream of reciprocating engine powered generating sets.
Bowman 'copper free' fuel coolers are compact, highly efficient heat exchangers suitable for fuel conditioning rigs in the automotive testing industry.
Engine coolant header tank heat exchangers for marine propulsion, gensets or stationary land-based engines.
Bowman EC 80-5113-1T heat exchangers provide a new solution for heating spas and hot tubs in just a fraction of the time taken by traditional electric heaters.
Highly efficient heat transfer solutions for cooling marine, land-based and underground hydraulic systems.
Bowman inline plate heat exchangers are a compact, economical solution for high efficiency heat transfer.
Bespoke cooling solutions for a range of popular marine engines from major OEMs, including coolant heat exchangers, charge air coolers, plus combined heat exchangers and exhaust manifolds, suitable for cooling marine engines up to 1 MW.
Bowman has a range of highly efficient oil coolers designed for marine and industrial engines and transmissions.
Efficient heat exchangers for cooling electric marine motors, hydrogen fuel cells, battery packs, chargers, AC-DC converters, DC-DC converters, inverters and associated equipment for electric and hybrid marine propulsion and charging systems.
Highly efficient heat transfer solutions for cooling a variety of applications where air and fluids need to be cooled by fluids.
Many applications require stainless steel shell and tube heat exchangers and Bowman provide a standard range of units that are suitable for cooling or heating a variety of fluids.
Bowman swimming pool heat exchangers are renowned for reliability and efficiency. Whether heating your pool with a traditional boiler or a renewable energy source, Bowman is the obvious choice.
Premium quality heat exchangers and oil coolers for precise temperature control of engines under test cell development conditions.
Recovering waste heat energy from engine powered generating sets for biogas, diesel and natural gas applications up to 1 MW.
Efficient cooling for stationary / land-based engines where air cooling is either unavailable or inappropriate.
The reliable solution for cooling Electric & Hybrid Marine Propulsion Systems.
A comprehensive oil cooling solution for industrial hydraulic control systems, plus high temperature and mining applications.
A complete solution for cooling complex on-board hydraulic equipment, including thruster and stabiliser systems.
The complete cooling solution for marine engine propulsion, including the latest electric and hybrid systems.
An energy efficient solution for heating hot tubs and swim spas faster, significantly reducing heat-up time for guest change-over periods.
Quality heat exchangers for efficient swimming pool heating, using boiler or renewable energy heat sources.
Easily integrated in to process pipework
Available quickly from our technical specialists
UK manufactured using 316 stainless steel
Suitable for transferring heat loads in excess of 50 kW

The intricate flow pattern through a series of stainless steel, vacuum-brazed heat transfer plates ensures that the units provide efficient transfer of heat between fluids at low flow rates.

The unique design of the internal water flow arrangement enables the inlet and outlet connections to be axially inline, so the unit fits simply and neatly into system pipework.

Manufactured from high quality 316 stainless steel, to Bowman's renowned standards, these neat, compact units provide high quality, long-lasting service.
The following information offers a general guide to the performance and dimensions of the standard product range of our inline plate type heat exchangers. For more detailed information on additional configurations please download the brochure. Computer aided selection software (CAS) can be used to accurately select the correct heat exchanger specifically for your application.
Please contact us or your nearest stockist with the following information to receive a specific product selection:
The image above is representative of Inline Plate Heat Exchanger models.
The figures given in the table are based on hot water entering the heat exchanger at 90 °C with cold water entering the heat exchanger at 20 °C at the specified flow rates. For more detailed drawings or dimensions, or to understand the performance of the units with alternative fluids and temperatures please download the brochure or contact us for further information.
| Model | Heat Dissipated (kW) | Water Flow (l/min) | Dim. A (mm) | Dim. B (mm) | Dim. C (mm) | Dim. D (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 10-9 | 6.5 | 10 | 106 | 50 | 51 | 1/2" | 0.9 |
| 10-9 | 11 | 20 | 106 | 50 | 51 | 1/2" | 0.9 |
| 15-5 | 6 | 20 | 158 | 75 | 66 | 3/4" | 2.5 |
| 15-5 | 8 | 30 | 158 | 75 | 66 | 3/4" | 2.5 |
| 15-9 | 16 | 30 | 158 | 75 | 86 | 3/4" | 2.9 |
| 15-9 | 20 | 40 | 158 | 75 | 86 | 3/4" | 2.9 |
| 15-13 | 23 | 30 | 158 | 75 | 106 | 3/4" | 3.3 |
| 20-5 | 11 | 40 | 215 | 100 | 81 | 1" | 5.4 |
| 20-9 | 22 | 40 | 215 | 100 | 107 | 1" | 6.1 |
| 20-13 | 31 | 40 | 215 | 100 | 133 | 1" | 6.8 |
| 20-17 | 38 | 40 | 215 | 100 | 159 | 1" | 7.6 |
| 20-21 | 44 | 40 | 215 | 100 | 185 | 1" | 8.4 |
| 20-25 | 48 | 40 | 215 | 100 | 211 | 1" | 9.2 |
| 20-29 | 52 | 40 | 215 | 100 | 237 | 1" | 10.2 |
| Model: 10-9 | Heat Dissipated (kW) 6.5 | Water Flow (l/min) 10 | Dim. A (mm) 106 | Dim. B (mm) 50 | Dim. C (mm) 51 | Dim. D (mm) 1/2" | Weight (kg) 0.9 |
| Model: 10-9 | Heat Dissipated (kW) 11 | Water Flow (l/min) 20 | Dim. A (mm) 106 | Dim. B (mm) 50 | Dim. C (mm) 51 | Dim. D (mm) 1/2" | Weight (kg) 0.9 |
| Model: 15-5 | Heat Dissipated (kW) 6 | Water Flow (l/min) 20 | Dim. A (mm) 158 | Dim. B (mm) 75 | Dim. C (mm) 66 | Dim. D (mm) 3/4" | Weight (kg) 2.5 |
| Model: 15-5 | Heat Dissipated (kW) 8 | Water Flow (l/min) 30 | Dim. A (mm) 158 | Dim. B (mm) 75 | Dim. C (mm) 66 | Dim. D (mm) 3/4" | Weight (kg) 2.5 |
| Model: 15-9 | Heat Dissipated (kW) 16 | Water Flow (l/min) 30 | Dim. A (mm) 158 | Dim. B (mm) 75 | Dim. C (mm) 86 | Dim. D (mm) 3/4" | Weight (kg) 2.9 |
| Model: 15-9 | Heat Dissipated (kW) 20 | Water Flow (l/min) 40 | Dim. A (mm) 158 | Dim. B (mm) 75 | Dim. C (mm) 86 | Dim. D (mm) 3/4" | Weight (kg) 2.9 |
| Model: 15-13 | Heat Dissipated (kW) 23 | Water Flow (l/min) 30 | Dim. A (mm) 158 | Dim. B (mm) 75 | Dim. C (mm) 106 | Dim. D (mm) 3/4" | Weight (kg) 3.3 |
| Model: 20-5 | Heat Dissipated (kW) 11 | Water Flow (l/min) 40 | Dim. A (mm) 215 | Dim. B (mm) 100 | Dim. C (mm) 81 | Dim. D (mm) 1" | Weight (kg) 5.4 |
| Model: 20-9 | Heat Dissipated (kW) 22 | Water Flow (l/min) 40 | Dim. A (mm) 215 | Dim. B (mm) 100 | Dim. C (mm) 107 | Dim. D (mm) 1" | Weight (kg) 6.1 |
| Model: 20-13 | Heat Dissipated (kW) 31 | Water Flow (l/min) 40 | Dim. A (mm) 215 | Dim. B (mm) 100 | Dim. C (mm) 133 | Dim. D (mm) 1" | Weight (kg) 6.8 |
| Model: 20-17 | Heat Dissipated (kW) 38 | Water Flow (l/min) 40 | Dim. A (mm) 215 | Dim. B (mm) 100 | Dim. C (mm) 159 | Dim. D (mm) 1" | Weight (kg) 7.6 |
| Model: 20-21 | Heat Dissipated (kW) 44 | Water Flow (l/min) 40 | Dim. A (mm) 215 | Dim. B (mm) 100 | Dim. C (mm) 185 | Dim. D (mm) 1" | Weight (kg) 8.4 |
| Model: 20-25 | Heat Dissipated (kW) 48 | Water Flow (l/min) 40 | Dim. A (mm) 215 | Dim. B (mm) 100 | Dim. C (mm) 211 | Dim. D (mm) 1" | Weight (kg) 9.2 |
| Model: 20-29 | Heat Dissipated (kW) 52 | Water Flow (l/min) 40 | Dim. A (mm) 215 | Dim. B (mm) 100 | Dim. C (mm) 237 | Dim. D (mm) 1" | Weight (kg) 10.2 |
The table below enables the selection of the most appropriate heat exchanger for your swimming pool or spa. The information shows the amount of heat that can be transferred from either boiler or renewable energy sources, together with the basic dimensions of each unit. Typical pool sizes are also shown as a guide. For further information please download the product brochure, contact us or your nearest stockist.
Note – Ratings and weight are specifically relevant to the titanium versions of each heat exchanger. Download the brochure for more detailed information.
Note – Ratings and weight are specifically relevant to the titanium versions of each heat exchanger. Download the brochure for more detailed information.
Note – Ratings and weight are specifically relevant to the titanium versions of each heat exchanger. Download the brochure for more detailed information.
Note – Weight provided are for the titanium versions.
For spas, hot tubs and small private pools
For mid sized private and commercial pools
For large commercial and public pools
For more information on JK190-5118-3 and PK190-5119-3 please contact Bowman.
For transferring heat from solar panels and heat pumps
For spas, hot tubs and small private pools
For mid sized private and commercial pools
For large commercial and public pools
For more information on JK190-5110-3 and PK190-5111-3 please contact Bowman.
For transferring heat from solar panels and heat pumps
No download content found.
Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.
Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.
Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.
Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.

Technical sales brochure includes product information, ratings charts, drawings and dimensions for the standard product range.
Selecting the correct heat exchanger is very important to ensure the pool heats up quickly to desired temperature. The main issues to consider when sizing a swimming pool heat exchanger are;
More information about heat exchanger selection, read the article ‘Why doesn’t my pool heat up faster?’
Selecting the correct heat exchanger is very important to ensure the pool heats up quickly to desired temperature. The main issues to consider when sizing a swimming pool heat exchanger are;
More information about heat exchanger selection, read the article ‘Why doesn’t my pool heat up faster?’
Selecting the correct heat exchanger is very important to ensure the pool heats up quickly to desired temperature. The main issues to consider when sizing a swimming pool heat exchanger are;
More information about heat exchanger selection, read the article ‘Why doesn’t my pool heat up faster?’

Bowman CHP heat exchangers provide vital heating for the Halley VI Antarctic research station.

If you can’t stand the heat – get a Bowman heat exchanger! How Bowman heat exchangers have solved a major cooling headache for a Portuguese river cruising company.

Bowman heat exchangers are delivering 21st century reliability and efficiency to an historic open air pool complex in South Wales.

A new ‘closed loop’ grain drying system, using Bowman heat exchangers has significantly reduced energy costs and improved efficiency in Finland.

Bowman CHP heat exchangers provide vital heating for the Halley VI Antarctic research station.

If you can’t stand the heat – get a Bowman heat exchanger! How Bowman heat exchangers have solved a major cooling headache for a Portuguese river cruising company.

Bowman heat exchangers are delivering 21st century reliability and efficiency to an historic open air pool complex in South Wales.

A new ‘closed loop’ grain drying system, using Bowman heat exchangers has significantly reduced energy costs and improved efficiency in Finland.
If you have a specific enquiry or would like to talk to one of our technical sales engineers, you can contact us by phone or email, using the contact details below. For more general enquiries, simply fill in and return the contact form for a fast response.
Tel: +44 (0)121 359 5401
E-mail: [email protected]
A network of authorised, international Bowman distributors, who hold product stocks and provide local service, is also available.